Fans for Oil Burners

Fans for Oil Burners

From time to time, someone asks which fan to use and comes up with the idea that a Chinese fan with speed control would be a good choice. No.

Gentlemen, when it comes to a fan for an oil burner, “power” and physical size are the last things you should be concerned with—unless we are talking about installation dimensions and how to fit it into a confined space near the boiler. The electrical power input of a fan does not indicate its actual performance, even though it is often presented that way on nameplates or in advertising materials. This is a fundamental misconception.

The so-called “power” of these fans merely expresses electrical energy consumption in watts. It does not specify the amount of air delivered, nor the operating overpressure.

For an oil burner to achieve the correct mixing ratio and for the flame to be at least blue, a truly capable fan is required—not a gimmick or a Chinese toy.

Not everyone succeeds in combusting the hydrogen and methane produced in oil vapors by pyrolysis and cracking. This is only possible with correct operating overpressures and controlled swirl, where regions of negative pressure also exist inside the burner as a result of the design itself. Achieving this requires a powerful fan.

Now we need to explain some basic concepts:

Operating overpressure, volumetric flow rate, and true fan performance

To properly understand the function of a fan in an oil burner, it is necessary to clarify several basic terms right at the beginning, as they are often confused or misinterpreted.

Operating overpressure is the pressure difference that the fan is capable of generating between its inlet and outlet. In practice, this means how much resistance the fan can “push through.” In an oil burner, this resistance is created by the nozzles, swirl channels, combustion chamber, and the flame itself. If the fan cannot generate sufficient overpressure, the air may spin freely, but it will not pass through the nozzles into the burner in the required quantity.

Volumetric flow rate indicates how much air the fan actually delivers per unit time, typically in cubic meters per hour. This value is meaningful only when related to a specific operating pressure. A flow rate measured without load—that is, without resistance—is practically worthless for burner design.

A simple practical example: why a weaker fan works better than a stronger one

For better understanding, let us consider a simple real-world example.

Imagine two fans. The first one, Fan A, has an electrical input of 80 W, large blades, and appears very powerful when running freely. With an unrestricted outlet, it can move a large amount of air, but its ability to generate pressure is low. Once connected to a burner with nozzles and swirl channels, its flow rate drops sharply because it cannot overcome the resistance of the construction. As a result, the burner lacks air where it is needed, the flame becomes unstable, smokes, or pulsates.

The second fan, Fan B, has an electrical input of only 40 W and appears weaker at first glance. It has smaller blades and does not feel as “strong” with a free outlet. However, it is designed for higher operating pressure. Once connected to the burner, it is able to actually force air through the nozzles and create the correct swirl and pressure conditions inside the combustion chamber. With this fan, the burner burns stably, the flame is compact, and it has the correct color.

The difference, therefore, is not in how many watts the fan consumes, but in what pressure it can generate at the required airflow. This is why, in oil burners, the pressure characteristic of the fan is decisive—not its electrical power input or its apparent “blowing” strength.

It is also essential to understand the difference between electrical input power and the aerodynamic performance of a fan. Electrical input power, stated in watts, only tells you how much electrical energy the fan draws from the supply. It says nothing about how much air the fan actually delivers or at what pressure. Aerodynamic performance, on the other hand, is the fan’s ability to generate pressure and airflow simultaneously. Two fans with the same electrical input can have completely different aerodynamic characteristics and will behave entirely differently in a burner.

For the entire process to function correctly, it is necessary to calculate the diameter and placement of the nozzles, their type, number, and installation angle in the burner. All of this is required to ensure that the flame does not pulsate, remains stable, and burns at the correct stoichiometric ratio. If you cannot perform these calculations and design work yourself, it is essential to work from manufacturing drawings or at least dimensioned sketches provided by a designer who takes responsibility for the design.

Beware of the various offered burner designs that have been copied countless times. Very often, even friends will tell you that they traced them correctly, built them, and that everything works flawlessly.

In reality, they often have no idea how an oil burner is supposed to work properly. Yet they will defend, for the rest of their lives, repeatedly redrawn and incorrectly published designs that are forty to sixty years old and full of errors. They are convinced of their own superiority simply because their burner burns with a blue-yellow flame and a heating output of around 8–9 kW per kilogram.

The best currently available technology (2026): the “Zejda 3” oil burner

They have never even heard of blue-transparent or blue-violet transparent flames produced by the combustion of hydrogen and methane with controlled oxygenation and NOx formation, which achieve the highest calorific value of approximately 11 kWh per kilogram. Or they reject these phenomena outright because they cannot even imagine them.

A poorly designed burner cannot be fixed, softened, or made acceptable by regulating the fan speed. Sometimes the burner may ignite, but it will never have the correct properties. A burner burns properly only with one specific fan with a given characteristic for which it was designed. That is the correct solution for home-built systems. Industrial installations are a different matter.

Therefore, you must be interested in the operating overpressure and the delivered air volume at which the fan operates.

This information is provided by fan performance curves, where one axis of the graph represents operating pressure and the other represents volumetric airflow. Fans with fixed rotational speed are characterized in this way.

With variable-speed fans, the situation is even more complicated. Trying to compensate for a poorly designed burner—with incorrectly placed nozzles, wrong diameters, or incorrect quantity—by using a speed-controlled fan is like tuning a Velorex. Yes, it can be done, but in terms of practical value, you are only wasting time and money.

Everything that needs to be done and how to do it is described in my book. An entire chapter is devoted to fans and their correct use. Everything is closely interconnected.

If you want to save money, buy solid, inexpensive Polish fans with declared specifications. The price ranges approximately between 1,000 and 1,200 CZK. The fan must be user-serviceable for cleaning and equipped with a backfire protection flap. Oil often contains water, which explodes in the burner. The flame then shoots out of the burner, most often toward the fan, which quickly becomes contaminated with dirt, ash, and oil mist and gradually fails if it is not cleaned regularly.

Performance and safety

A fan clogged with oil mist and dust on the blades has significantly reduced performance, and the burner then does not burn properly. This is also described in the operating instructions and service manual.

These are both performance and safety necessities of modern times. You do not want authorities knocking on your door simply because smoke comes out of the chimney during burner ignition or shutdown. It is not only the steady-state operating mode that matters, but also these transitional combustion regimes of an oil burner.

From a safety standpoint, it is also essential that the fan has a long service life and is capable of continuously delivering sufficient air at the correct operating overpressure. If the fan fails, combustion quality deteriorates severely, leading to rapid fouling of the heat exchanger and flue gas passages with oily, greasy soot. This can accumulate within just a few hours. Under suitable conditions, it can then ignite similarly to pure carbon, at temperatures reaching up to 4,000 °C, aided by chimney draft. As a result, the chimney may crack, and flue gases can subsequently spread into living spaces.

The choice of safety, reliability, and efficiency is therefore also directly linked to selecting the right fan.


📍 English navigation block (EN):

✅ Get Access to the Technical Work – License Included

(Protected technical work prepared individually, verified access, license terms, and secure delivery with password.)

⚙️ Zejda Burner Models – Overview & Videos
(All Zejda series burners + technical specs + demo videos)

❓ FAQ – Questions & Answers
(Most common practical questions about burners)

📘 Oil Burners – Foreword
(Introduction for all readers, why this project exists)

🔥 Flame Colors, Temperatures & Combustion
(How flame color relates to combustion quality and emissions)

🧯 Oil Burner Safety – Key Principles
(Safety tips and combustible risks with oil burners, dioxines)

🔬 Emissions & NOx Reduction Techniques
(How to reduce NOx and other pollutants, The Secret)

📏 Measurements & Testing Methods
(How to measure emissions and performance, Phenomena, Dripping Water)

🛠️ Construction, Materials & Maintenance
( Fans, Pyrolytic versus atomizing burner, Materials of high-temperature burners)

💬 Key Technical Principle of High-Temperature Pyrolytic Oil Combustion
( Description of burner technologies)

🛠️ Oil burner and the most suitable hot water boiler
(
Boilersfor of high-temperature burners)

Comments

Napsat komentář