FAQ – Frequently Asked Questions and Answers by the Designer, Developer, and User pyrolytic wortex waste oil burner with blue flame

Zejda Oil Burners – Technical, Operational, and Licensing Information


Introduction

This document contains the most frequently asked questions regarding the purchase, design, and operation of multi-chamber vortex pyrolytic oil burners of the Zejda 1–3 system, intended for burning used oils, light fuel oil (LFO), and selected types of heavier oils.

Prodejní stránka olejové hořáky Zejda
Olejový hořák Zejda 3

The answers are based on long-term design practice, operational experience, and the physical principles of combustion. The purpose of this FAQ is to help the reader assess whether this type of technology is suitable for their intended use, while clearly defining the technical, operational, and legal boundaries of its application.

Author of the answers: Filip Zejda


A. Purchase, Trust, and Licensing

1. Why is it not possible to see the burner at a public demonstration before purchase?

Zejda system oil burners are not mass-produced products, but rather a set of design principles, proportions, and construction details. These can be partially inferred even from a simple visual inspection.

Past experience has shown that even short public demonstrations led to unauthorized copies, which often did not function correctly and damaged both the reputation of the technology and its author. For this reason, no open demonstrations or public workshops are organized.

Instead, explanatory texts, articles, and videos describing the combustion principles are publicly available. Detailed construction procedures are provided only after the purchase of a license.


2. Why are there no publicly available user reviews?

Most users deliberately choose to remain anonymous. The main reasons are practical:

  • burning used oils is a legislatively sensitive topic,
  • users want to avoid unnecessary disputes or inspections,
  • license terms discourage public disclosure of construction details.

Feedback exists within direct communication between the author and licensed users and is used for further development and documentation updates. A public group focuses on environmentally responsible burning of used oils.


3. How can I tell this is not a scam?

The decisive criterion is the content. This project openly describes the physical and chemical combustion processes, including their limitations. It does not promise universal solutions or miracles and does not avoid discussing risks and operational demands.

Olejový hořák Zejda 3 s kvalitním spalováním použitých olejů
Spalování olejů

The author is publicly traceable, contact details have been functional for many years, and the technology is based on more than twelve years of development. Such a level of open information is neither typical nor sustainable for fraudulent projects.


4. Is a refund possible if I fail to build or commission the burner?

No. The subject of the sale is not a finished product, but licensed access to knowledge and technical documentation for three types of Zejda oil burners, which cannot be returned once access is granted.

As with professional literature or technical manuals, it is not possible to request a refund after the information has been studied. Successful construction depends primarily on adherence to proportions, workmanship, and understanding of the principles involved.


5. Can I have individual burner parts welded by a professional welder?

Yes, but only under strict know-how protection conditions:

  • the builder must be personally present during welding,
  • the welder must not have access to complete drawings or documentation,
  • key components (the plate with chamber) and (the inner vessel with jacket) must not be welded by the same person.

Violation of these conditions constitutes a breach of the license agreement.


B. Operation and Compatibility

6. Is the burner suitable for intermittent operation, and can it be installed in Viadrus boilers?

The burner is primarily designed for continuous operation. Efficient oil combustion requires stable temperature and vortex conditions. Intermittent operation is not suitable, is energy-intensive, and leads to reduced efficiency and increased residue formation.

Power regulation is recommended to be continuous in the range of approximately 25–100 % or achieved via heat accumulation. With minor modifications, the burner can be installed in stationary gas boilers with cast-iron heat exchangers, including Viadrus boilers.


7. What power output and temperatures does the burner achieve?

In a four-section cast-iron boiler, Zejda Burner 1 and Zejda Burner 2 achieve approximately 10–27 kW with one fan and up to 40 kW with two fans. Flue gas temperature before the heat exchanger is around 800 °C. Zejda Burner 3 has an output of approximately 6–20 kW.

Olejový hořák Zejda 1
Provoz hořáku na olejovou emulzi

Local peak temperatures in turbulent zones of the blue-gray to blue-violet flame can briefly exceed 2300 °C. These are not average combustion temperatures but localized maxima typical of the high-temperature gaseous combustion phase.


C. Noise

8. How noisy is the burner during operation?

Noise is primarily determined by the fans used. In videos, it may appear louder due to microphone proximity. In typical residential spaces, noise levels are usually low. The quietest operation is achieved with the Zejda 3 design when using high-quality fans.


D. Power, Efficiency, and Maintenance

9. How long can the burner operate without cleaning?

Operating time depends on the burner type and fuel quality. For Zejda 1 and 2 models, cleaning is recommended after one operating cycle, no later than after 24 hours. With a properly adjusted Zejda 3 burner, operation can be extended up to 72 hours.

Cleaning is quick and involves removing dry, brittle ash and any deposits. When correctly adjusted, no liquid residues or tar remain in the burner.


E. Fuel and Consumption

10. What types of fuel can be burned?

The burner is optimized for used oil, LFO, and selected heavier oils (after preheating). Most petroleum-based industrial oils can be burned, including hydraulic, transmission, or compressor oils, and to a limited extent even oils contaminated with water.

The user is always responsible for verifying which fuels are legal in their country.


11. What is the fuel consumption?

Consumption ranges approximately from 1.0 to 3.5 liters of oil per hour, depending on output and burner type. Usable energy output typically ranges from approximately 10–11.5 kWh per liter of oil, depending on the entire combustion system.


F. DIY Construction

12. Are technical drawings available, and how much does construction cost?

The electronic book contains detailed hand-drawn sketches with dimensions and notes. No specialized machinery is required; standard workshop equipment is sufficient.

When using reclaimed materials as described in the book, material costs can be very low, but in practice they vary depending on material availability, chosen design, and the builder’s equipment.


G. Safety and Emissions

13. What about emissions, and why are no official measurements provided?

Emissions cannot be objectively determined for the burner alone without a specific installation. Results depend on boiler type, fuel, chimney draft, operating mode, and other factors such as cleaning intervals (24 or 72 hours depending on the oil used).

Proper high-temperature pyrolytic combustion is indicated by a continuous blue flame, dry ash, and a long-term clean heat exchanger. These indicators are more reliable than a single generalized numerical value.


H. Criticism, Emotions, and Misconceptions

14. Why is there so much emotion surrounding this technology?

Emotions arise from the encounter of different approaches—established technologies, experimental development, and environmental concerns. Zejda technology operates on a different combustion principle, which naturally raises questions and sometimes resistance.

The difference between chaotic oil burning and controlled high-temperature decomposition of oil vapors is not always widely understood. This distinction is the key to understanding the function of Zejda burners.


I. License and Support

15. Is user support available?

Yes. Licensed users can communicate directly with the author via e-mail and receive documentation updates. Consultations are paid. Updates reflect long-term development and practical operational experience.


Conclusion

This FAQ summarizes basic technical, operational, and licensing information. Detailed construction procedures, safety rules, and extended technical explanations are included in the electronic book and licensing documentation.


Legal Disclaimer

This documentation is intended exclusively for informational and educational purposes. It does not constitute instructions for manufacturing a certified combustion device nor an approved technological procedure under applicable legislation.

The author assumes no responsibility for the manner in which the described principles are used, for specific construction designs, or for the operation of devices built on their basis. Full responsibility for compliance with safety regulations, technical standards, and legal requirements lies with the operator of the equipment.

Fuel usage, installation, and operation must always comply with the legal regulations applicable in the given country and location of installation.


📍 English navigation block (EN):

✅ Get Access to the Technical Work – License Included

(Protected technical work prepared individually, verified access, license terms, and secure delivery with password.)

⚙️ Zejda Burner Models – Overview & Videos
(All Zejda series burners + technical specs + demo videos)

❓ FAQ – Questions & Answers
(Most common practical questions about burners)

📘 Oil Burners – Foreword
(Introduction for all readers, why this project exists)

🔥 Flame Colors, Temperatures & Combustion
(How flame color relates to combustion quality and emissions)

🧯 Oil Burner Safety – Key Principles
(Safety tips and combustible risks with oil burners, dioxines)

🔬 Emissions & NOx Reduction Techniques
(How to reduce NOx and other pollutants, The Secret)

📏 Measurements & Testing Methods
(How to measure emissions and performance, Phenomena, Dripping Water)

🛠️ Construction, Materials & Maintenance
( Fans, Pyrolytic versus atomizing burner, Materials of high-temperature burners)

💬 Key Technical Principle of High-Temperature Pyrolytic Oil Combustion
( Description of burner technologies)

🛠️ Oil burner and the most suitable hot water boiler
(
Boilersfor of high-temperature burners)

Comments

Napsat komentář

Vaše e-mailová adresa nebude zveřejněna. Vyžadované informace jsou označeny *