Sustained high-temperature combustion enabled by volcanic ash microstructures guiding pyrolytic gas flow.
after more than 24 hours of continuous operation, something very interesting begins to occur in the “Zejda 1” and “Zejda 2” burners—that is, in both pyrolytic swirl burners—specifically in the lowest combustion chamber, the pyrolytic chamber. I would like to share this phenomenon with you.
In this part of the burner, structures strikingly reminiscent of miniature volcanoes begin to form from ash and flue gas deposits as a result of prolonged exposure to high temperatures.

These “volcanoes” phenomena usually contain several main channels beneath the surface, along with numerous smaller side passages through which pyrolytic gases escape toward the flue. The volcano’s own “chimney”—which I will dare to call a vent—can reach a height of approximately 20 to 35 mm.
Their actual size can be clearly assessed in a photograph taken on graph paper, where one square measures 5 × 5 mm.
Around the main vent, smaller parasitic craters often appear, releasing hot gases in a manner similar to fumaroles in real volcanoes. These gas emissions originate from a boiling oil bath at temperatures of approximately 200–300 °C. The entire structure is very fragile and easily disintegrates if handled roughly. On fractured pieces, one can often observe the early formation of another parasitic crater that is just beginning to grow.
What Is Actually Happening in This Part of the Burner?
Oil flowing into the pyrolytic section of the combustion chamber initially undergoes partial evaporation, primarily in the temperature range of 150–300 °C. Within this range, only the lightest oil fractions evaporate. Combustion here involves light hydrocarbons, oil aerosol, and residual fuels originating from gasoline and diesel engines.

The result is a relatively calm flame: the nozzles do not clog, and carbon deposits are minimal. The drawback of this operating mode, however, is that heavier oil components remain in the liquid phase, leading to a low overall energy yield of the burner. This is precisely where the story of many simple, home-built oil burners ends—due to insufficient understanding of combustion processes.
Increasing Temperature: Entering the Pyrolysis Regime
To truly utilize the heavier oil fractions, it is necessary to structurally increase the temperature in the lowest combustion chamber. Once temperatures reach approximately 300–600 °C, thermal decomposition processes known as pyrolysis begin to occur in the medium-heavy oil fractions.
In our case, this is predominantly low-temperature pyrolysis up to about 500 °C. Pyrolysis is a process in which organic substances thermally decompose in the absence of oxygen or under very low oxygen concentrations. The products are gases, liquid compounds, and solid carbonaceous residues.
Thermal Cracking and the Formation of Carbonaceous Deposits
For the heaviest oil fractions, roughly in the temperature range of 450–700 °C, processes occur that can be described as a combination of medium-temperature pyrolysis and thermal cracking. The extent of these processes depends strongly on temperature and reaction time.
Cracking is a process in which long, complex molecules of heavy oil components are broken down into smaller, lighter molecules with lower boiling points. The products include gases such as hydrogen (H₂), carbon monoxide (CO), methane (CH₄), ethylene (C₂H₄), aromatic hydrocarbons, and solid carbon—coke.

These reactions can be locally very intense and, in some cases, exothermic, leading to localized overheating and the formation of carbonaceous deposits commonly referred to as pyrolytic char. In certain cases, these deposits may contain a small fraction of inorganic components whose character can resemble “ceramics”—this again depends on the composition of the oil used.
At even higher temperatures, carbonization becomes dominant in the heaviest fractions, meaning the conversion of organic material primarily into solid carbon. In the case of used oils, these processes often overlap and cannot be cleanly separated—real-world chemistry is simply more complex than tabulated descriptions suggest.
The “Volcanic” Structure as a Gas-Phase Reactor
The branched channels within the ash layer, together with the vents and parasitic craters, act as microreactors in which high-temperature conditioning of gases for subsequent combustion takes place. A simple rule applies here: the longer and more intricate these channels are, the greater their porosity and the rougher their internal surfaces, the higher the quality of the gaseous mixture produced for downstream combustion.
At the same time, cracking proceeds within the swirl of hot flue gases that are drawn back into the lower part of the burner at high velocity and temperature. This mechanism explains why, during long-term operation of the “Zejda 1” and “Zejda 2” burners—even after more than 24 hours of continuous firing—the combustion process in the final, fully oxygenated, visually observable chamber does not significantly deteriorate.
The reason lies in the multi-chamber design: each combustion chamber operates at a different temperature, oxygen concentration, and operating pressure, all of which are also influenced by local swirl flow patterns. Each chamber therefore fulfills a specific role within the overall process.
Why a Temperature of Around 400 °C Is Ideal
In the lowest pyrolytic chamber, it is desirable to maintain a temperature of approximately 400 °C. This is achieved through strong swirling flows of recirculated flue gases and through appropriately designed nozzles with suitable flame length and characteristics.
In this operating regime, the following processes occur simultaneously:
- evaporation of light fractions,
- pyrolysis of heavier and heaviest fractions,
- and favorable molecular transformations associated with thermal cracking.
Conversely, under domestic operating conditions, it is not advisable to exceed temperatures above approximately 500 °C in this lowest zone above the oil level. Doing so would lead to carbonization and clogging of the oil inlet. This would require additional mechanical devices to break up the carbon layer—undesirable in a simple domestic burner design.
Final Combustion Zone: “Blue Flame Plasma” in Quotation Marks
From the above, it follows that a multi-chamber burner design, in which the user controls oil supply, air quantity and pressure, and the configuration of individual chambers, is fully sufficient to achieve a controlled combustion process.
The result is a gaseous, blue-white, highly turbulent annular “flame wall”, whose appearance resembles plasma. This is not plasma in the strict physical sense, but rather an extremely hot, highly turbulent flame with excess air, enhanced by a swirl generator. Temperatures in this region can reach on the order of 2000–2300 °C.
All flue gases generated in the preceding pyrolytic chambers must pass through this combustion zone. With proper adjustment, a heating value of approximately 10–11 kWh per kilogram of oil can be achieved—values close to the theoretical energy potential of the fuel.
The entire process can be governed by the burner’s design and correct operational practice alone, without the need for complex electronic control systems—provided that the operator is properly trained and the operating manual is followed.
Conclusion oil burner vocanic phenomena
For these reasons, I consider the design of the pyrolytic swirl burner to be suitable for domestic use as well—exclusively, however, by trained builders and operators working under a licensing agreement, using approved design documentation and operating manuals supplemented with instructional videos demonstrating correct operation.
Note:
In reality, the entire process is even more complex, and the description presented here does not encompass all reactants or all phenomena involved. The stated observations reflect the current level of my knowledge, practical experience, and understanding of the subject.
Filip Zejda
Designer of the system:
“Pyrolytic Swirl Oil Burner for Used Oils with a Blue Flame”
📍 English navigation block (EN):
✅ Get Access to the Technical Work – License Included
(Protected technical work prepared individually, verified access, license terms, and secure delivery with password.)
⚙️ Zejda Burner Models – Overview & Videos
(All Zejda series burners + technical specs + demo videos)
❓ FAQ – Questions & Answers
(Most common practical questions about burners)
📘 Oil Burners – Foreword
(Introduction for all readers, why this project exists)
🔥 Flame Colors, Temperatures & Combustion
(How flame color relates to combustion quality and emissions)
🧯 Oil Burner Safety – Key Principles
(Safety tips and combustible risks with oil burners, dioxines)
🔬 Emissions & NOx Reduction Techniques
(How to reduce NOx and other pollutants, The Secret)
📏 Measurements & Testing Methods
(How to measure emissions and performance, Phenomena, Dripping Water)
🛠️ Construction, Materials & Maintenance
( Fans, Pyrolytic versus atomizing burner, Materials of high-temperature burners)
💬 Key Technical Principle of High-Temperature Pyrolytic Oil Combustion
( Description of burner technologies)
🛠️ Oil burner and the most suitable hot water boiler
( Boilersfor of high-temperature burners)


Napsat komentář